TagMeter Systems is aware that a proper Prepayment or Prepaid system consist of two components:
- Prepayment or Prepaid Meters (Hardware)
- Software Management System (Software)
Many times the Software Management System is forgotten.In our opinion the Software System is essential.
We have spend over 50 man-year in developing a true cash flow generating software system CFM32©, which is capable of managing meters, customers and Tags or Transponders.
Because the meters write data back onto the Tag, the management system is able to read in this information and statistics and reports can be generated.
We know that every customer like water board or municipality has its own wish-list. Therefore we made our system flexible. We are able and willing to adapt our system and add tailor made or custom designed items and/or procedures.
Connection with other systems is not a problem.
New in CFM32 Revision 3.21b (February 2011) is the Zoning module.
Purpose of the Zoning Module is that a specific transponder can be used only for a specific meter or for a range of specific meters which have been defined in a so-called Zone.
The following relations between Transponder Tag and Meter are possible:
- one-to-one relationship; Each meter has been parameterized as a specific zone. Each Transponder Tag also has been defined as a UserTag of a specific zone. The meter will operate only if the same zone in both Meter and Transponder Tag match.
- one-to-many relationship; Several meters have been assigned as a zone. Only one specific Transponder tag has been defined as a specific zone. The meters defined in the zone can be operated with the same Transponder Tag
- many-to-one relationship; A specific meter has been defined as a unique zone. Several Transponder Tags have been defines as a UserTag of that specific zone. The meter will operate only if the same zone in both Meter and Transponder Tag match. Example: a family has one meter and 4 UserTags. Each of those UserTags have been defined as a Zone 01 UserTag. The meter also has been defined as a Zone 01 meter and unique: only one meter has zone 01. Now all 4 family members can use the UserTag to operate the meter, providing the meter is not locked by a specific family member, but not the meter of the neighbours.
- many-to-many relationship; Several meters have been assigned and parameterized as a zone. Several UserTags have been assigned as UserTags to be used in a specific zone. Now all those UserTags can operate all meters defined in that specific zone, providing the meter has not been locked by a UserTag. It is not possible that User 01 inserts the UserTag, valve in the meter opens and is locked for User 01. If User 02 inserts the UserTag than the meter will not operate this Transponder unless the credits in the meter are empty.
Further implemented are Individual Emergency Credits and Individual Low Credits alarm.